HomeMy WebLinkAbout17-3650 ordORDINANCE NO. 17-3650 AN ORDINANCE OF THE CITY COUNCIL FOR THE CITY OF PLAINVIEW AMENDING CHAPTER 3, ARTICLE 3.04, DIVISION 6, NATIONAL ELECTRICAL CODE AND ARTICLE 3.05, DIVISIONS 5 AND 6, INTERNATIONAL PLUMBING CODE, OF THE CITY OF PLAINVIEW CODE OF ORDINANCES; TO ADOPT THE NATIONAL ELECTRICAL CODE (2014 EDITION) AND THE INTERNATIONAL PLUMBING CODE (2015 EDITION); REPEALER; CUMULATIVENESS CLAUSE; SEVERABILITY CLAUSE; CONFLICTS CLAUSE, AND EFFECTIVE DATE. WHEREAS, Chapter 3, Building Regulations, of the Plainview Code of Ordinances set forth the minimum standards for building construction; and WHEREAS, from time to time it is advisable to review the ordinances that regulate construction of all buildings within the City of Plainview; and WHEREAS, the City of Plainview's Building Trades and Fire Code Board of Appeals has reviewed staff recommendations on adoption of the National Electrical Code (2014 Edition) and the International Plumbing Code (2015 Edition), for updating building regulations within the City; and WHEREAS, the 2014 National Electrical Code and the 2015 International Plumbing Code, with proposed amendments as hereinafter made, have been duly presented to the City Council; and WHEREAS, the City Council finds that it would be in the best interest of their citizens to adopt such ordinance as hereinafter stated, and that not doing so could be detrimental or injurious to the public health, safety or general welfare of the citizens of the City of Plainview: NOW, THEREFORE, The City of Plainview hereby ordains that: SECTION I ARTICLE 3.04, Electricity, of the Plainview Code of Ordinances is hereby amended as follows: Division 6. Electrical Code and Installation Regulations Sec. 3.04.161 Electrical code adopted Ail installation hereafter installed within the corporate limits of the city shall be done in first class workmanlike manner in accordance with the 2008 2014 edition of the National Electrical Code, as adopted by the National Fire Protection Association, Ord. No. 17-3650 2014 Electrical Code/2015 Plumbing Code Page 1 of 7 169 170 and said National Electrical Code is made a part of this article, with the additions and deviations therefrom contained in this code. SECTION 11 ARTICLE 3.05, Plumbing, of the Plainview Code of Ordinances is hereby amended as follows: Division 5. Plumbing Code and General Regulations Sec. 3.05.121 Plumbing code adopted All installation hereinafter installed within the corporate limits of the city shall be done in a first class workmanlike manner in accordance with the 2000 2015 edition of the International Plumbing Code as adopted by the International Code Council, and said lntemational Plumbing Code and incorporated references and appendixes is made of part of this article, with the additions and deviations therefrom contained in this code. Sec. 3.05.122 Conformance with plumbing code All plumbing systems hereafter installed shall conform with the provisions of the 2009 2015 edition of the International Plumbing Code, as amended. Sec. 3.05.123 Amendments Amendments to the 2009 2015 International Plumbing Code shall be as follows: Section 106.6.3 Fee refunds. Insert "zero (0)" percent at Section 106.6.3.2 and "fifty (50)" percent at Section 106.6.3.3. Section 108.4 (d). Enforcement. Delete "the electrical inspector." Section 108.5. Stop work orders. Upon notice from the code official, work on any plumbing system that is being done contrary to the provisions of this code or in a dangerous or unsafe manner shall immediately cease. Such notice shall be in writing and shall be given to the owner of the property, or to the owner's agent, or to the person doing the work. The notice shall state the conditions under which work is authorized to resume. Where an emergency exists, the code official shall not be required to give a written notice prior to stopping the work. Any person who shall continue any work in or about the structure after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable for a fine as specified in Section 1.01.009 of the City of Plainview Code of Ordinances. Ord. No. 17-3650 2014 Electrical Code/2015 Plumbing Code Page 2 of 7 9 0 Suction 100.1 Applicat+on for appeal. Amend to read as follows: City of Plainview -Building Tradosra -Fi fie-Bear-+ef-Appc ls. See article 3.02 of the City of Plainview Code of Ordinances. SECTION 109. MEANS OF APPEAL. Delete this section in its entirety and replace with the following wording: In order to hear and decide appeals of orders, decisions or determinations made by the Buildinc_Official relative to the application and interpretation of this code, an appeal must be filed with the Building Trades and Fire Code Board of Appeals in accordance with Article 3.02 in the City of Plainview Code of Ordinances. Section 305.4.1 Sewer depth. Building sewers shall be a minimum of 12 inches (305 mm) below grade. Section 312.2. Drainage and vent water test. A water test shall be applied to the drainage system either in its entirety or in sections. If applied to the entire system, all openings in the piping shall be tightly closed, except the highest opening, and the system shall be filled with water to the point of overflow. If the system is tested in sections, each opening shall be tightly plugged except the highest openings of the section under test, and each section shall be filled with water, but no section shall be tested with less than a 5 foot (1524 mm) head of water. In testing successive sections, a lowest opening head test at each floor level if multiple floors shall be tested at the plumbing rough -in inspection . This test shall be held for not less than 15 minutes. Section 312.10.1 Inspections. Annual inspections shall be made of all backflow prevention assemblies and air gaps to determine whether they are operable. In the absence of local provisions, the owner is responsible to ensure that testing is performed. Section 312.10.2 Testing. Reduced pressure principle backflow preventer assemblies, double check -valve assemblies, pressure vacuum breaker assemblies, reduced pressure detector fire protection backflow prevention assemblies, double check detector fire protection backflow prevention assemblies, hose connection backflow preventers, and spill -proof vacuum breakers shall be tested at the time of installation, immediately after repairs or relocation and at least annually. The testing procedure shall be performed in accordance with applicable local provisions. In the absence of local provisions, the owner is responsible to ensure that testing is done in accordance with one of the following standards: ASSE 5013, ASSE 5015, ASSE 5020, ASSE 5047, ASSE 5048, ASSE 5052, ASSE 5056, CSA B64.10 or CSA B64.10.1 or CSA B64.10.1. Section 608.16.5_ Connections to law , Insert the fe w+eg to the end of the section : Double check valve backflow prcvontor, Section 702.1 Above- ground sanitary drainage and vent pipe. Above -ground soil, waste and vent pipe shall conform to one of the standards listed in Table 702.1. Ord. No. 17-3650 2014 Electrical Code/2015 Plumbing Code Page 3 of 7 171 172 Table 702.1 ABOVE -GROUND DRAINAGE AND VENT PIPE PIPE STANDARD Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS ASTM D 2661; ASTM F 628; ASTM F 1488; diameters, including schedule 40, DR 22 (P5 200) and DR 24 CSA B181.1 (P5 140); with a solid seNblarsere°or composite wall Cast-iron pipe ASTM A 74; CISPI 301; ASTM A 888 Copper or copper -alloy pipe ASTM B 42: ASTM B 302 Copper or copper -alloy tubing (Type K, L, M or DWV) ASTM B 75; ASTM B 88; ASTM B 251; ASTM B 306 ASTM F 1412; CSA B181.3 Galvanized steel pipe ASTM A 53 Polyolefin pipe CSA 8181.3 Polyvinyl chloride (PVC) plastic pipe in IPS diameters, ASTM D 2665; ASTM F 891; CSA 6181.2; including schedule 40, DR 22 (PS 200) and DR 24 (PS 140); ASTM F 1488 with a solid cellular -sere -or composite wall Polyvinyl chloride (PVC) plastic pipe with a 3.25 inch O.D. and ASTM D 2949; ASTM F 1488 a solid sellalar-sere-or composite wall ASME A 112.3.1 Stainless steel drainage systems. Types 304 and 316L ASME A 112.3.1 Section 702.2 Underground building sanitary drainage and vent pipe. Underground building sanitary drainage and vent pipe shall conform to one of the standards listed in Table 702.2. TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE PIPE STANDARD Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS ASTM 0 2661; ASTM F 628; ASTM F 1488; diameters, including schedule 40, DR 22 (PS 200) and DR 24 CSA B181.1 (PS 140); with a solid sell -War -safe -or composite wall _ Cast-iron pipe ASTM A 74; CISPI 301; ASTM A888 Copper or copper alloy tubing (Type K. L. M or DWVI ASTM B 75; ASTM B 88; ASTM B 251; ASTM B 306 Polyolefin pipe ASTM F 1412; CSA B181.3 Polyvinyl chloride (PVC) plastic pipe in IPS diameters, including ASTM 0 2665; ASTM F 891; ASTM F 1488; schedule 40, DR 22 (PS 200) and DR 24 (PS 140); with a solid CSA 8181.2 cellular or composite wall Polyvinyl chloride (PVC) plastic pipe with a 3.25 inch O.D. and a ASTM D 2949; ASTM F 1488 solid Gellularcero or composite wall Polyvinvlidene fluoride (PVDF) plastic pipe ASTM F 1673; CSA 8181.3 Stainless steel drainage systems, Type 316L ASME A 112.3.1 Section 702.3 Building sewer pipe. Building sewer pipe shall conform to one of the standards listed in Table 702.3. Ord. No. 17-3650 2014 Electrical Code/2015 Plumbing Code Page 4 of 7 173 TABLE 702.3 BUILDING SEWER PIPE MATERIAL STANDARD Acrylonitrile butadiene styrene (ABS) plastic pipe in IPS ASTM D 2661; ASTM F 628; ASTM F 1488 diameters, including schedule 40, DR 22 (P5 200) and DR 24 (PS 140); with a solid, cellular core -or composite wall Cast-iron pipe ASTM A 74; ASTM A 888; CISPI 301 e Acrylonitrile butadiene styrene (ABS) plastic pipe in sewer ASTM F 1488; ASTM D 2751 and drain diameters, including SDR 42 (PS 20). PS35. SDR 35 (PS 45), PS50, PS100, PS140, SDR 23.5 (PS 150) and PS200; with a solid cedar sere -or composite wall Polyvinyl chloride (PVC) plastic pipe in sewer and drain ASTM F 891; ASTM F 1488; ASTM D 3034; diameters, including PS 25, SDR 41 (PS 28), PS 35, SDR 35 (PS 46), PS 50, PS CSA B182.2; CSA B182.4 100, SDR 26 (PS 115), PS140 and PS 200; with a solid Concrete pipe ASTM C 14; ASTM C 76; CSA A257.1 M; CSA A257.2M Copper or copper -alloy tubing (Type K or L) ASTM B 75; ASTM B 88; ASTM B 251 Polyethylene (PE) plastic pipe (SDR -PR) ASTM F 714 Polyolefin pipe ASTM F 1412; CSA B181.3 Polyvinyl chloride (PVC) plastic pipe in IPS diameters` ASTM D 2665; ASTM D 2949; ASTM D 3034; including schedule 40, DR 22 (PS 200) and DR 24 (PS ASTM F 1412; CSA B182.2; CSA B182.4 140); with solid sellulaf Gere -pr composite wall Polyvinyl chloride (PVC) plastic pipe with a 3.25 inch O.D. ASTM D 2949, ASTM F 1488 and a solid cellular core -or composite wall Stainless steel drainage systems, Types 304 and 316L ASME A 112.3.1 Section 903.1 Roof extension. All open vent pipes that extend through a roof shall be terminated at least 12 inches (305 mm) above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof. Division 6. Materials Sec.3.05.141 Minimum standards The materials used shall conform with the standards set forth in the 2003 2015 edition of the Uniform International Plumbing Code, unless amended in this article. Sec. 3.05.142 Materials not listed Materials other than those listed in the 2003 2015 Uniform International Plumbing Code may be permitted upon approval of the building trades and fire code board of appeals. Ord. No. 17-3650 2014 Electrical Code/2015 Plumbing Code Page 5 of 7 174 SECTION III All ordinances or parts of ordinances inconsistent with any provisions of this ordinance are hereby repealed to the extent of such conflict, and the provisions of this ordinance shall be and remain controlling as to the matters regulated herein. SECTION IV Provisions of this Ordinance are cumulative and nothing herein shall prevent, alter, or diminish the applicability or enforcement of other ordinances restricting, regulating, or governing the subject matter herein. SECTION V Severability is intended throughout and within this Ordinance. If any provision, including any section, paragraph, sentence, clause, phrase or word or the application thereof to any person or circumstance is held invalid, unconstitutional, or unenforceable by a court of law or administrative agency with jurisdiction over the matter, such action shall not be construed to affect any other valid portion of this Ordinance. A constitutional construction hereof is intended and shall be given. There is not intent herein to violate either of the Texas Constitution or the Constitution of the United States. SECTION VI All ordinances or portions of any ordinance of the City of Plainview, Texas in conflict herewith, are hereby amended to conform with the provisions hereof. SECTION VII This ordinance shall be of full force and effect upon its passage and publication as required by law. PASSED AND APPROVED on first reading this 14th day of March, 2017. PASSED AND APPROVED on second reading this 28th day of March, 2017. ATTEST: 711, Belinda Hinojosa, City Secretary Ord. No. 17-3650 i en. a Dunlap, Mayor 2014 Electrical Code/2015 Plumbing Code Page 6 of 7 C APPROVED AS TO CONTENT: Cris Val erde, Community Development Manager APPROVED AS TO FORM: (44/46,Th liekIN6-obt Leslie Spear Schm dt, City Attorney f Ord. No. 17-3650 2014 Electrical Code/2015 Plumbing Code Page 7 of 7 175